1-1. Unit Specifi cations
PE1
6. Low Silhouette Ducted Type S-100PF1E5 / U-100PE1E5
INDOOR
OUTDOOR
Branch pipe
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
CURRENT
INPUT POWER
C
ANNUAL CONSUMPTION
O
EER/EER CLASS
O
Pdsign
L
Erp
SEER
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
CAPACITY
CURRENT
INPUT POWER
H
COP/COP CLASS
E
Pdsign
A
Tbivalen
T
Erp
SCOP
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
I/D AIR
COOL
FLOW
HEAT
O/D AIR
COOL
FLOW
HEAT
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Operation
Condition
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
MODEL
S-100PF1E5
MODEL
MODEL
ø, Hz
1ø 50Hz
V
220
kW
10.0
BTU/h
34100
A
1.35
W
195
TOTAL W
TOTAL W
4
TOTAL(W/W) 5/("A"~"G")
-
kW
-
(W/W)
-
kWh
-
-
%
-
dB-A
38/34/31
Power Level dB
60/56/53
dB-A
Power Level dB
kW
11.2
BTU/h
38200
A
1.37
W
200
TOTAL W
TOTAL(W/W) 5/("A"~"G")
-
kW
-
°C
-
(W/W)
-
kWh
-
-
%
-
dB-A
38/34/31
Power Level dB
60/56/53
dB-A
Power Level dB
1.80/265
1.75/265
-
L/h(Pt/h)
6.0
Pa
100 (MIN10 - MAX150)
3
3
m
/min (ft
/min)
32
m
3
/min (ft
3
/min)
32
3
3
m
/min (ft
/min)
3
3
m
/min (ft
/min)
290 (11-13/32)
1400 (55-1/8)
700 (27-9/16)
Cool O.D(DBT)
18°C ~ 32°C
Heat O.D(DBT)
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
ISO5151
230
240
220
10.0
10.0
34100
34100
1.30
1.27
11.0
195
195
2.245k
-
2.440k
-
-
-
-
4.10
-
-
-
-
-
-
-
-
-
-
-
-
-
-
93
11.2
11.2
38200
38200
1.34
1.29
11.6
200
200
2.400k
-
2.600k
-
-
4.31
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
94
-
-
-
1.70/265
25.0/5.350k
-
-
11.6/3.0k
-
200
(12.6)
(1130)
(1130)
110
95
R410A
355
1614
850
45
54
9 (10)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 75
(16.4 ~ 246.1)
50
(537.6)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-124
U-100PE1E5
-
1ø 50Hz
230
240
Min
3.3
11300
10.6
10.3
2.245k
2.245k
2.440k
2.440k
840
1220
-
4.10 / A
4.10
3.93
10.0
-
5.8
-
603
-
A+
-
92
91
-
-
52/-
69/-
4.1
14000
11.2
10.7
2.400k
2.400k
2.600k
2.600k
900
4.31 / A
4.31
4.56
10.0
-
-10
-
3.8
-
3684
-
A
-
94
93
-
-
52/-
69/-
25.0/5.550k
25.0/5.750k
11.2/3.0k
10.7/3.0k
-
90×2
-
(3885)
(3355)
3.40k
(119.9)
1416 (55-3/4)
940 (37-1/32)
340 (13-13/32)
1556
1055
485
98
108
1 (2)
-15°C ~ 46°C
-20°C ~ 24°C
~
(49.2/98.4)
Max
12.5
42700
-
-
-
-
3.700k
-
-
3.38
-
-
14.0
47800
-
-
-
-
4.400k
3.18
-
-
/
/
/
/
/
/
/
/
/
~