Panasonic S-45PU1E5 Technical Data & Service Manual page 250

Table of Contents

Advertisement

1
Single -Type
1-1. Unit Specifi cations
PEY1
7. Ducted Type S-140PN1E5 / U-140PEY1E8
INDOOR
PANEL
OUTDOOR
Branch pipe
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
CURRENT
INPUT POWER
C
ANNUAL CONSUMPTION
O
EER/EER CLASS
O
Pdsign
L
Erp
SEER
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
CAPACITY
CURRENT
INPUT POWER
H
COP/COP CLASS
E
Pdsign
A
Tbivalen
T
Erp
SCOP
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
COOL
I/D AIR
FLOW
HEAT
O/D AIR
COOL
FLOW
HEAT
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Operation
Condition
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
MODEL
S-140PN1E5
MODEL
MODEL
MODEL
ø, Hz
1ø 50Hz
V
220
kW
14.0
BTU/h
47800
A
1.89
W
250
TOTAL W
TOTAL W
4
TOTAL(W/W) 5/("A"~"G")
-
kW
-
(W/W)
-
kWh
-
-
%
-
dB-A
46/44/39
Power Level dB
67/65/60
dB-A
Power Level dB
kW
14.0
BTU/h
47800
A
1.89
W
250
TOTAL W
TOTAL(W/W) 5/("A"~"G")
-
kW
-
°C
-
(W/W)
-
kWh
-
-
%
-
dB-A
46/44/39
Power Level dB
67/65/60
dB-A
Power Level dB
2.59/0.345k
2.53/0.345k
-
L/h(Pt/h)
9.0
Pa
50 (MIN10 ~ MAX80)
m
3
/min (ft
3
/min)
40
3
3
m
/min (ft
/min)
40
3
3
m
/min (ft
/min)
m
3
/min (ft
3
/min)
250 9-27/32
1200 (+100) 47-1/4 (+3-15/16)
650 25-19/32
Cool O.D(DBT)
18°C ~ 32°C
Heat O.D(DBT)
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
ISO5151 / EN14511 / EN12012
230
240
380
14.0
14.0
47800
47800
1.82
1.74
7.05
250
250
4.450k
-
4.700k
-
-
-
-
2.98
-
-
-
-
-
-
-
-
-
-
-
-
-
-
96
14.0
14.0
47800
47800
1.82
1.74
5.90
250
250
3.730k
-
3.980k
-
-
3.52
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
96
-
-
-
2.47/0.345k
10.0/6.200k
-
-
7.05/3.0k
-
200
(18.9)
(1413)
(1413)
135
120
R410A
338
1402
761
41
48
6 (7)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164.0)
50
(537.6)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-240
U-140PEY1E8
-
3ø 50Hz
400
415
Min
3.3
11300
6.70
6.45
-
4.450k
4.450k
-
4.700k
4.700k
840
2350
-
-
2.98 / C
2.98
3.93
-
-
-
-
-
-
-
-
96
96
-
-
-
54/-
71/-
4.1
14000
5.60
5.40
-
3.730k
3.730k
-
3.980k
3.980k
900
3.52 / B
3.52
4.56
-
-
-
-
-
-
-
-
-
-
96
96
-
-
-
53/-
70/-
10.0/6.500k
10.0/6.750k
6.70/3.0k
6.45/3.0k
-
90×2
-
(4767)
(4238)
3.40k
(119.9)
1416 55-3/4
940 37-1/32
340 13-13/32
1556
1055
485
98
108
1 (2)
-10°C ~ 43°C
-15°C ~ 24°C
~
(49.2/98.4)
Max
15.5
52900
-
-
6.000k
-
2.58
-
16.0
54600
-
-
5.200k
3.08
-
/
/
/
/
/
/
/
/
/
~

Hide quick links: