1
Simultaneous (Twin) -Type
1-1. Unit Specifi cations
PEY1
3. Ceiling Type S-50PT1E5×2 / U-100PEY1E5
INDOOR
PANEL
OUTDOOR
Branch pipe
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
CURRENT
INPUT POWER
C
ANNUAL CONSUMPTION
O
EER/EER CLASS
O
Pdsign
L
Erp
SEER
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
CAPACITY
CURRENT
INPUT POWER
H
COP/COP CLASS
E
Pdsign
A
Tbivalen
T
Erp
SCOP
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
NOISE OUTDOOR
(H/L)
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
COOL
I/D AIR
FLOW
HEAT
O/D AIR
COOL
FLOW
HEAT
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Operation
Condition
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
MODEL
S-50PT1E5×2
MODEL
MODEL
MODEL
ø, Hz
1ø 50Hz
V
220
kW
10.0
BTU/h
34100
A
0.42×2
W
41×2
TOTAL W
TOTAL W
4
TOTAL(W/W) 5/("A"~"G")
-
kW
-
(W/W)
-
kWh
-
-
%
-
dB-A
38/33/30
Power Level dB
57/51/46
dB-A
Power Level dB
kW
10.0
BTU/h
34100
A
0.42×2
W
41×2
TOTAL W
TOTAL(W/W) 5/("A"~"G")
-
kW
-
°C
-
(W/W)
-
kWh
-
-
%
-
dB-A
39/34/30
Power Level dB
57/51/47
dB-A
Power Level dB
0.42×2/41×2 0.41×2/41×2 0.41×2/41×2 25.0/5.300k
-
L/h(Pt/h)
6.0
Pa
m
3
/min (ft
3
/min)
14×2
3
3
m
/min (ft
/min)
14×2
3
3
m
/min (ft
/min)
m
3
/min (ft
3
/min)
210 8-9/32
910 35-13/16
680 26-25/32
Cool O.D(DBT)
18°C ~ 32°C
Heat O.D(DBT)
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
CZ-P155BK1
ISO5151 / EN14511 / EN14825
230
240
220
10.0
10.0
34100
34100
0.41×2
0.41×2
16.2
41×2
41×2
3.377k
-
3.460k
-
-
-
-
2.89
-
-
-
-
-
-
-
-
-
-
-
-
-
-
95
10.0
10.0
34100
34100
0.41×2
0.41×2
12.6
41×2
41×2
2.628k
-
2.710k
-
-
3.69
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
95
-
-
-
-
-
16.2/1.7k
-
40×2
(3.0×2)
(12.6)
-
(494)×2
(494)×2
76
67
R410A
280
985
780
21 (46)
73
24 (53)
81
11 (12)
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
5 ~ 50
(16.4 ~ 164.0)
50
(537.6)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-182
U-100PEY1E5
1ø 50Hz
230
240
15.5
14.6
3.376k
3.375k
3.460k
3.460k
1730k
-
2.89 / C
2.89
10.0
-
5.9
-
593
-
A+
-
95
96
-
-
54/-
70/-
12.0
11.5
2.627k
2.626k
2.710k
2.710k
3.69 / A
3.69
9.5
-
-7
-
3.8
-
3500
-
A
-
95
95
-
-
54/-
70/-
25.0/5.500k
25.0/5.700k
15.5/1.7k
14.6/1.7k
-
90
-
(2684)
(2366)
2.60k
(91.7)
996 (39-7/32)
940 (37-1/32)
340 (13-13/32)
1136
1055
485
(161)
(179)
2 (3)
-10°C ~ 43°C
-15°C ~ 24°C
fl ared type, 5.0(16.4)
(49.2/98.4)
Min
Max
2.7
11.5
9200
39200
-
-
-
-
530
4.200k
-
-
5.09
2.74
-
-
2.1
13.8
7200
47100
-
-
-
-
410
4.000k
5.12
3.45
-
-
/
/
/
/
/
/
/
/
/
~
~