Panasonic S-45PU1E5 Technical Data & Service Manual page 475

Table of Contents

Advertisement

1-13. Capacity Table
1. Cooling Capacity Performance Data
Combination of Single Unit
Ducted Type
Ambient
Power
Model
Return
Source
DB
23
25
220V
230V
S-50PN1E5
240V
27
U-50PE1E5
50Hz
1 phase
29
32
25°C
Air
WB
TC
SHC
IPT
TC
16
5.9
4.3
1.85
5.6
19
6.4
3.3
1.93
6.0
22
7.0
2.4
2.01
6.5
16
5.9
5.0
1.85
5.6
19
6.4
3.9
1.93
6.0
22
7.0
3.0
2.01
6.5
16
5.9
5.6
1.85
5.6
19
6.4
4.6
1.93
6.0
22
7.0
3.6
2.01
6.5
16
5.9
5.9
1.85
5.6
19
6.4
5.1
1.93
6.0
22
7.0
4.2
2.01
6.5
16
5.9
5.9
1.85
5.6
19
6.4
5.1
1.93
6.0
22
7.0
4.2
2.01
6.5
Outdoor air intake temp(°C D.B.)
30°C
35°C
SHC
IPT
TC
SHC
IPT
4.2
2.01
5.2
4.0
2.22
3.2
2.10
5.6
3.0
2.31
2.2
2.18
6.1
2.0
2.40
4.8
2.01
5.2
4.6
2.22
3.8
2.10
5.6
3.6
2.31
2.8
2.18
6.1
2.6
2.40
5.4
2.01
5.2
5.2
2.22
4.4
2.10
5.6
4.2
2.31
3.4
2.18
6.1
3.2
2.40
5.6
2.01
5.2
5.2
2.22
5.0
2.10
5.6
4.8
2.31
4.0
2.18
6.1
3.8
2.40
5.6
2.01
5.2
5.2
2.22
5.0
2.10
5.6
4.8
2.31
4.0
2.18
6.1
3.8
2.40
1-465
TC
:Cooling Capacity
SHC :Sensible Heat Capacity
IPT :Cooling Power Consumption
unit : kW
40°C
46°C
TC
SHC
IPT
TC
SHC
5.0
3.9
2.46
3.9
3.4
5.4
2.9
2.56
4.2
2.5
5.9
2.0
2.67
4.6
1.5
5.0
4.5
2.46
3.9
3.9
5.4
3.5
2.56
4.2
3.1
5.9
2.6
2.67
4.6
2.1
5.0
5.0
2.46
3.9
3.9
5.4
4.1
2.56
4.2
3.7
5.9
3.2
2.67
4.6
2.7
5.0
5.0
2.46
3.9
3.9
5.4
4.7
2.56
4.2
4.2
5.9
3.8
2.67
4.6
3.3
5.0
5.0
2.46
3.9
3.9
5.4
4.7
2.56
4.2
4.2
5.9
3.8
2.67
4.6
3.3
1
IPT
1.62
1.68
1.75
1.62
1.68
1.75
1.62
1.68
1.75
1.62
1.68
1.75
1.62
1.68
1.75

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents