Panasonic S-45PU1E5 Technical Data & Service Manual page 87

Table of Contents

Advertisement

Simultaneous (Twin) -Type
1-1. Unit Specifi cations
PE1
4. Ceiling Type S-71PT2E5×2 / U-140PE1E5
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION
TOTAL W
O
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
O
Pdsign
L
Erp
SEER
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
COOL
m
3
/min (ft
I/D AIR
FLOW
3
HEAT
m
/min (ft
3
O/D AIR
COOL
m
/min (ft
FLOW
HEAT
m
3
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-71PT2E5×2
-
ø, Hz
1ø 50Hz
V
220
230
kW
14.0
14.0
47800
47800
A
0.45×2
0.44×2
W
55×2
55×2
-
4
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
39/35/31
57/53/49
dB-A
kW
16.0
16.0
54600
54600
A
0.45×2
0.44×2
W
55×2
55×2
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
39/35/31
57/53/49
dB-A
-
-
0.45×2/55×2 0.44×2/55×2 0.43×2/55×2
-
-
-
74
L/h(Pt/h)
9.0
(4.5×2)
Pa
-
3
/min)
21×2
3
/min)
21×2
3
/min)
3
/min)
235
1275
690
360
1340
820
33
42
9 (10)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
-
U-140PE1E5
CZ-P155BK1
ISO5151 / EN14825
1ø 50Hz
240
220
230
14.0
47800
0.43×2
21.2
20.5
55×2
4.540k
4.540k
4.650k
4.650k
-
2325
-
3.01
3.01 / B
-
-
-
-
-
-
-
-
-
-
-
-
-
97
96
54/-
71/-
16.0
54600
0.43×2
19.9
19.2
55×2
4.250k
4.250k
4.360k
4.360k
-
3.67
3.67 / A
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
97
96
-
-
55/-
71/-
-
30.0/6.40k
30.0/6.62k
-
21.2/3.0k
20.5/3.0k
-
90×2
(18.9)
-
(742)×2
(742)×2
135
120
R410A
3.40k
9-1/4
1416 55-3/4
50-3/16
940 37-1/32
27-5/32
340 13-13/32
1556
1055
485
(73)
98
(93)
108
1 (2)
-15°C ~ 46°C
-20°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 75
(16.4 ~ 246.1)
(49.2/98.4)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-77
240
Min
Max
3.3
15.0
11300
51200
19.9
-
-
4.540k
-
-
4.650k
840
5.650k
-
-
-
3.01
3.93
2.65
-
-
-
-
95
-
-
4.1
18.0
14000
61400
18.6
-
-
4.250k
-
-
4.360k
900
5.930k
3.67
4.56
3.04
-
-
-
-
-
95
-
-
30.0/6.84k
19.8/3.0k
(4767)
(4238)
(119.9)
/
/
/
/
/
/
/
(216)
/
(238)
/
~
~
1