Simultaneous (Twin) -Type
1-1. Unit Specifi cations
PE1
4. Ceiling Type S-36PT2E5×2 / U-71PE1E5
INDOOR
MODEL
PANEL
MODEL
OUTDOOR
MODEL
Branch pipe
MODEL
PERFORMANCE TEST CONDITION
POWER SUPPLY
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
C
ANNUAL CONSUMPTION
TOTAL W
O
EER/EER CLASS
TOTAL(W/W) 5/("A"~"G")
O
Pdsign
L
Erp
SEER
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
CAPACITY
BTU/h
CURRENT
INPUT POWER
TOTAL W
H
COP/COP CLASS
TOTAL(W/W) 5/("A"~"G")
E
Pdsign
A
Tbivalen
T
Erp
SCOP
(W/W)
I
6
Annual consumption
N
Class
G
POWER FACTOR
NOISE INDOOR
(H/M/L)
Power Level dB
NOISE OUTDOOR
(H/L)
Power Level dB
EXTRA LOW TEMP Total CAPACITY(kW)/INPUT POWER(W)/COP
MAX CURRENT(A)/MAX INPUT POWER(W)
STARTING CURRENT(A)/COMP OUTPUT(W)
NETWORK IMPEDANCE (ΩMAX.)
FM OUTPUT (W)
MOISTURE REMOVAL VOLUME
External static pressure
COOL
m
3
/min (ft
I/D AIR
FLOW
3
HEAT
m
/min (ft
3
O/D AIR
COOL
m
/min (ft
FLOW
HEAT
m
3
/min (ft
REFRIGERANT TYPE, AMOUNT g(oz)
HEIGHT : H mm(inch)
P
D
R
I
WIDTH : W mm(inch)
O
M
DEPTH : D mm(inch)
HEIGHT : H mm
P
D
A
I
WIDTH : W mm
C
M
DEPTH : D mm
(NET) kg(lb)
MASS
(GROSS) kg(lb)
LAYERS LIMIT (actually)
Cool O.D(DBT)
Operation
Condition
Heat O.D(DBT)
PIPE DIAMETER mm (inch)
P
CONNECT METHOD, STD LENGTH m (ft)
I
PIPE LENGTH RANGE
P
I
I/D&O/D HEIGHT DIFFERENCE m (ft)
N
ADD GAS AMOUNT g/m (oz/ft)
G
PIPE LENGTH FOR ADDITIONAL GAS m (ft)
*1: In case it is necessary to indicate the air fl ow volume in (l/s), the value in (m
*2: If the EUROVENT Certifi ed models can be operated under the "extra-low" temperature condition, -7°C dry bulb and -8°C wet-bulb temperatures with rated voltage
230 V shall be used.
*3: Network Impedance shall be applicable for EUROPE and CHINA models.
*4: The annual consumption is calculated by multiplying the input power at 230 V (400 V) by an average of 500 hours per year in cooling mode.
*5: EER and COP classification is at 230 V (400 V) only in accordance with EU directive 2002/31/EC.
*6: SEER and SCOP classification is at 230V(400V) only in accordance with EN-14825. For heating, SCOP indicates the value of only Average heating season,
Other fiche data indicates in an attached sheet.
S-36PT2E5×2
-
ø, Hz
1ø 50Hz
V
220
230
kW
7.1
7.1
24200
24200
A
0.37×2
0.36×2
W
35×2
35×2
-
4
-
-
-
kW
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
36/32/29
54/50/47
dB-A
kW
8.0
8.0
27300
27300
A
0.37×2
0.36×2
W
35×2
35×2
-
-
-
kW
-
-
°C
-
-
-
-
kWh
-
-
-
-
%
-
-
dB-A
36/32/29
54/50/47
dB-A
-
-
0.37×2/35×2 0.36×2/35×2 0.35×2/35×2
-
-
-
43
L/h(Pt/h)
4.2
(2.1×2)
Pa
-
3
/min)
14×2
3
/min)
14×2
3
/min)
3
/min)
235
960
690
360
1025
820
27
34
9 (10)
18°C ~ 32°C
16°C ~ 30°C
(Liquid)ø6.35(1/4) (Gas)ø12.7(1/2)
fl ared type, 5.0(16.4)
m (ft)
15 (OD located lower) / 30 (OD located higher)
U-71PE1E5
CZ-P155BK1
ISO5151 / EN14825
1ø 50Hz
240
220
230
7.1
24200
0.35×2
9.00
8.70
35×2
1.875k
1.875k
1.945k
1.945k
-
973
-
3.65
3.65 / A
-
-
7.1
-
-
6.2
-
-
401
-
-
A++
-
95
94
48/-
65/-
8.0
27300
0.36×2
8.90
8.60
35×2
1.875k
1.875k
1.945k
1.945k
-
4.11
4.11 / A
-
-
7.1
-
-
-9
-
-
4.0
-
-
2485
-
-
A+
-
96
95
50/-
67/-
-
18.0/3.76k
18.0/3.89k
-
9.00/2.0k
8.70/2.0k
90
(8.8)
(494)×2
(494)×2
60
60
R410A
2.35k
9-1/4
996 39-7/32
37-25/32
940 37-1/32
27-5/32
340 13-13/32
1136
1055
485
(60)
69
(75)
77
2 (3)
-15°C ~ 46°C
-20°C ~ 24°C
(Liquid)ø9.52(3/8) (Gas)ø15.88(5/8)
fl ared type, 5.0(16.4)
5 ~ 50
(16.4 ~ 164)
(49.2/98.4)
50
(0.538)
30
(98.4)
3
/min.) shall be multiplied by 16.7 and rounded down the decimal point.
1-67
-
240
Min
2.5
8500
8.40
-
1.875k
-
1.945k
450
-
-
3.65
5.56
-
-
-
-
93
-
2.0
6800
8.30
-
1.875k
-
1.945k
400
4.11
5.00
-
-
-
-
-
94
-
-
-
18.0/4.02k
8.40/2.0k
-
-
(2119)
(2119)
(82.9)
/
/
/
/
/
/
/
(152)
/
(170)
/
~
1
Max
8.0
27300
-
-
2.780k
-
2.88
-
9.0
30700
-
-
2.900k
3.10
-
~