4) Temperature control at Energy Saving Mode
This equipment has the following two types of temperature control for saving energy and returns to
ready status to perform printing in each mode upon printing request.
The period of time from the printing request to this mode can be set in "Setting Mode (08)" or by an
administrator.
Administrator setting procedure:
[USER FUNCTIONS] button o [ADMIN] (input of administrator's password) o [GENERAL] o
[ENERGY SAVER]
Auto Power Save Mode (Setting Mode (08-205)):
When the printing is not performed in a specified period of time (default setting: 15 min.) after the
previous printing is completed, the equipment enters to Auto Power Save Mode to turn OFF the
heater lamp.
Auto Shut Off Mode (Setting Mode (08-206)):
When the printing is not performed in a specified period of time (default setting: 60 min
(e-STUDIO230/232/280/282 series
entered to Auto Power Save Mode, the equipment then enters to Auto Shut Off Mode to turn OFF
the heater lamp.
*1
For e-STUDIO232/282 for MJD, "40 minutes" is set by default.
Warming-up
°C
180
Temperature
of fuser roller
Heater lamp
ON
0
June 2004 © TOSHIBA TEC
*1
), 30 min (e-STUDIO200L/202L series)). after the equipment
Ready
During printing
Fig.13-5
13 - 7
05/11
Auto Power Save Mode
( Heater lamp OFF )
Fixed time ( 08-205 )
Fixed time ( 08-206 )
e-STUDIO200L/202L/230/232/280/282 FUSER UNIT
Auto
Shut Off
Mode
OFF