(3)
Remove 1 screw. Disconnect 1 connector
while taking off the recovered toner drive
unit. Remove 1 gear.
(4)
Remove 2 plate springs fixing the doctor
sleeve on its both ends.
(5)
Remove 2 screws on both ends of the doctor
sleeve and remove 2 coil springs.
Note:
When the screws on both ends of the doctor
sleeve are removed, be sure to adjust the
doctor sleeve gap (0.45±0.05 mm) after
assembling.
(Refer to Service Handbook Chap. 3.9)
June 2004 © TOSHIBA TEC
Gear
Recovered toner drive unit
Fig.12-17
Plate spring
Fig.12-18
Coil spring
Screw
Fig.12-19
e-STUDIO200L/202L/230/232/280/282 DEVELOPMENT SYSTEM
12 - 13
Connector
Plate spring
Coil spring
Screw