Toshiba e-STUDIO 200L Service Manual page 182

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO 200L:
Table of Contents

Advertisement

(5)
Rotate the carriage-2 in the direction where
the inside of the frame is dented shown in
the figure at right, not to touch the mirror.
Then take off the carriage-2.
[J]
Mirrors-2 and -3
(1)
Take off the carriage-2
(
P.6-25 "[I] Carriage wire / Carriage-2").
Note:
When replacing the mirrors-2 and -3, replace
them together with the carriage-2. The mir-
rors-2 and –3 should not be removed sepa-
rately.
[K] Platen sensor
(1)
Take off the rear cover an upper rear cover
(
P.2-31 "[C] Rear cover",
Upper rear cover").
(2)
Disconnect 1 connector from the platen sen-
sor on the left rear position of the equipment
upper side.
(3)
Release the latches of the sensor and take
off the platen sensor.
e-STUDIO200L/202L/230/232/280/282 SCANNER
P.2-34 "[I]
Platen sensor
6 - 26
Carriage-2
Fig. 6-43
Fig. 6-44
June 2004 © TOSHIBA TEC