6.2

Flush mounting

Siemens Building Technologies
Fire & Security Products
The unit should be installed on a surface that is as even as possible.
Procedure
Slot the connection board into the bottom section of the housing with the
terminals facing downwards. To do this gently push the locating hooks apart with
your fingers.
Connect the cable to the terminal strip in the bottom section of the housing
(see chapter „5.1 Connecting the reader").
Plug the top section onto the bottom section of the housing. In doing so, insert
the male connector of the reader electronics cleanly into socket connector X3 on
the terminal board!
Do not mount the unit to the wall before you have checked the set-up
works.
Remove the top section of the housing from the bottom section.
Screw the bottom section of the housing incl. the snapped terminal board onto
the base, using 3 x 16 mm self-tapping screws.
Plug the top section onto the bottom section of the housing. In doing so, insert
the male connector of the reader electronics cleanly into socket connector X3 on
the terminal board!
Screw in the safety screw on the underneath of the bottom section of the
housing.
Note:
The maximum torque of the safety screw is 1.5 Nm.
Fig. 3
Back view of the bottom section of the housing
with the terminal board snapped in
Socket connector X3
Installation
9
12.2004