Siemens AR6181-MX Installation And Configuration Manual page 17

Table of Contents

Advertisement

DIP 7
DIP 8
on
off
CerPass protocol (RS485)
UCI protocol (RS485)
Clock/Data: Omron
Clock/Data: Wiegand
DIP 7
on
CerPass protocol (RS485)
UCI protocol (RS485)
Clock/Data: Omron
Clock/Data: Wiegand
Siemens Building Technologies
Fire & Security Products
ID number, BCD (4 bit) or
ID number
ASCII format
(7 bit)
ID number
BCD-format
(4 bit)
ID number
BCD (4 bit) or
ASCII (7 bit)
format
ID number
BCD (4 bit) or
ASCII (7 bit)
format
Please note:
Within this selection only ISO14443A cards with personalized application data
within a sector/block or a block will be read.
The ID number is an information written by the user into the read/write area of the
qualified transponders / cards (Write areas sector/block or block within qualified
transponders / cards).
No reaction or malfunction will be at the reader AR6181-MX if other coded cards
are presented.
DIP 8
on
ID number, BCD (4 bit) or SIPASS (7 bit) coded data
ID number
BCD format
(4 bit)
ID number
ASCII format
(7 bit)
Impermissible
Impermissible
Please note:
Within this selection only ISO14443A cards with personalized application data
within a sector/block or a block will be read.
The ID number is an information written by the user into the read/write area of the
qualified transponders / cards (write areas sector/block or block within qualified
transponders / cards).
No reaction or malfunction will be at the reader AR6181-MX if other coded cards
are presented.
Information to be read
ASCII
(7 bit) coded data
Max. 16 characters of information,
transmitted as a 7 bit ASCII format
Max. 32 digits of information,
transmitted as a 5 bit ABA format
Transmitted as every 4 bit (half byte) in a 5 bit ABA format. ASCII formatted
data will be transmitted in two halves (high/low half byte of ASCII character)
means as two digits per char.
Transmitted without conversion as bit stream of coded data
Information to be read
Max. 16 numeric digits (value 0 . . . 9) of information,
transmitted as a 7 bit ASCII format;
Each digit is send as one numeric ASCII character
Max. 16 characters of information,
transmitted as a 7 bit ASCII format,
Option: Conversion of older SIPASS card format
DIP switch settings
Card type
ISO14443A
Card type
ISO14443A
17
12.2004

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar6182-mx

Table of Contents