Horizontal Top Contact Connector - Lexmark MX910de Service Manual

Hide thumbs Also See for MX910de:
Table of Contents

Advertisement

Horizontal top contact connector

This connector uses a back flip locking actuator to lock the ribbon cable into the ZIF connector.
Warning—Potential Damage: When opening or closing this type of actuator, lift or close the two tabs located on
each end of the actuator. The two tabs should be moved simultaneously. Do not close the actuator from the center.
Removing the cable
1
Unlock the actuator.
2
Remove the cable.
Inserting the cable
Make sure that the actuator is unlocked before installing the cable. The tabs are vertical when the actuator is locked.
1
Insert the cable on top of the actuator with the contacts facing up.
Note: Make sure that the cable is installed squarely into the connector to avoid intermittent failures.
Repair information
249
7421

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx911dteMx912dxeMx91xXm91x5

Table of Contents