Cabling Ip4Ww-080E-B1; Figure 2-74 Connectors Of 080E-B1 - NEC SL1100 Hardware Manual

Hide thumbs Also See for SL1100:
Table of Contents

Advertisement

ISSUE 5.0
• Use cable protectors in case the cables run on the floor.
• Aerial distribution wiring is not allowed.
• Trunks must be installed with lightning protectors.
• Do not install the DSX Terminal in the SL1100 system, it does not work properly.

3.4.1 Cabling IP4WW-080E-B1

This IP4WW-080E-B1 PCB provides two RJ-61 connections for digital extensions.
Before plugging in the Multiline Telephone, DSS Console, Single line
Telephone or Doorphone, ensure all Main and Expansion KSUs are powered
off.
DSX Terminal does not work properly when it connected.
3.4.1.1 Connectors
The following table shows the pin-outs for the RJ-61 cable connector for Digital extension connections.
Hardware Manual
J102 J101
ESI 5-8 ESI 1-4
5
4 3
6 2
Port 1 Port 2 Port 3 Port 4
T
R
T: Tip
R: Ring
Modular Cable
(2-wire, Straight)