Charging rates will vary depending on how long the
battery has been stored, temperature, and the type of
charger used.
Let battery sit 30 minutes after initial charge, then check
voltage using a voltmeter.
If it is not at least 12.8 V, repeat charging cycle.
After charging is completed, press down firmly with
both hands to seat the strip of caps "A" into the
battery (don't pound or hammer.). When properly
installed, the strip of the caps will be level with the
top of the battery.
Once the strip of the caps "A" is installed onto the
battery, never remove the caps, nor add water or
electrolyte to the battery.
To ensure maximum battery life and customer
satisfaction, it is recommended the battery be load tested
at three times its amp-hour rating for 15 seconds.
Re-check voltage and if less than 12.8 V repeat the
charging cycle and load test.
If still below 12.8 V the battery is defective.