6-1-6. Platen Motor
Disassemble
1.
Remove the one Screw, one Cord Holder 6N (2), and remove the one Screw and the Cord Holder 5N (3).
3
2.
Disconnect the Harness (4) and remove it from the clamps below. Disconnect the Platen Motor
Connector (CN4).
Clamp
(4)
Connector for Platen Motor (CN4)
3.
Remove the Nut 2 M4 (5) and the Bolt Socket (6) for adjusting the tension of the Belt.
2
(6)
(5)
GT-3 Series
6. Replacing Parts
Clamps