3. Operation

3-1-5. Description of the Advanced Menu

The following pages show the additional information of the Advanced Menu.
Operate the buttons on the Panel as the User Menu.

3-1-5-1. CR Origin Sensor Adjustment

This menu adjusts the detecting position of the Origin Sensor; which defines the origin of the Carriage.
The Origin Sensor detects the sealed area on the Encoder Strip when you turn ON the printer. The position of
the sealed area has been adjusted in manufacturing but the position may shift by dismounting the Encoder
PCB and replacing the Encoder Strip. Execute this adjustment after you modify the printer. Be sure to execute
this after you replace the Main PCB.
Without this adjustment, the position of the Caps and print may shift in horizontal direction. If you find that only
the capping position should shift, adjust the position of the Maintenance Unit first.

3-1-5-2. Firmware Update

In general situation the firmware is upgraded from PC with "GT-3 Firmware Update". Use this function when
PC is not available, or the firmware should be downgraded, which cannot be done with PC tool.
Refer to the "3-2. Firmware Update" for further information.

3-1-5-3. Output Check

This menu can operate some of the movable parts individually to confirm the output function of the printer.
The following menu is identical for all models; you can even activate the Solenoid Ink Ret_W Assy on the
GT-341.
No.
Menu
1
Cap Test
2
Wiper Test
3
Carriage Test
4
Solenoid Test

3-1-5-4. Input Check

This menu can show the status of some sensors to confirm if the sensor is available.
The following menu is identical for all models; you can even show the status of Wiper Cleaner if it is mounted.
No.
Menu
1
Carriage / Platen
2
Maintenance Unit
78
Moves up and down the Caps on the Maintenance Unit
Moves back and forth the Wipers on the Maintenance Unit
Moves the Carriage to "Capping position", "Flushing position" and "the
Center of the Platen"
Activates the Solenoid one by one: "Clearance Flap Solenoid, "White
Ink Retrieval Solenoid", "Maintenance Unit Solenoid"
Indicates the status ON/OFF of CR Origin Sensor, Clearance Flap,
Platen Origin, the position of Encoder Sensor and the value of
Temperature Sensor.
<Note>
The Caps are moved down automatically when you select this menu
and moved up automatically when you close this menu. This operation
is to make the Carriage free and confirm the position of the Encoder
Sensor.
Indicates the status ON/OFF of Wiper Origin Sensor, Cap Origin
Sensor, Pump Rotation Sensor, Wiper Cleaner SW of White/Color.