Error Resetting Conditions - Mitsubishi Electric MELSERVO MR-J2S- A Instruction Manual

General-purpose ac servo general-purpose interface servo amplifier
Table of Contents

Advertisement

15. ABSOLUTE POSITION DETECTION SYSTEM
(c) To detect the ABS time-out warning (AL.E5) at the servo amplifier, the time required for the ABS
request signal to go OFF after it has been turned ON (ABS request time) is checked. If the ABS
request remains ON for longer than 1s, it is regarded that an fault relating to the ABS request
signal or the send data ready (TLC) has occurred, and the ABS communication error is generated.
The ABS communication error occurs if the ABS time-out warning (AL.E5) is generated at the
servo amplifier due to an ABS request OFF time time-out.
ABS transfer mode
ABS request
Send data ready
ABS communication
error

15.10.2 Error resetting conditions

Always remove the cause of the error before resetting the error.
Name
ABS communication error
ABS checksum error
ABS coordinate error
Servo alarm
ON
OFF
ON
OFF
ON
OFF
YES
NO
Output coil
AD71
1PG
Y49
Y11
Y4A
Y12
Y4B
Y48
Y10
1s
The signal does
not go OFF
Servo status
Ready (RD) off
Ready (RD) on
Ready (RD) on
Ready (RD) on
15 - 65
Resetting condition
Reset when servo-on (SON) PB
(X36) signal turns off.
For AD71
Reset when servo-on (SON) PB
(X36) signal turns from off to on.
For FX-1PG
Reset when servo-on (SON) PB
(X36) signal turns off.
Reset when servo-on (SON) PB
(X36) signal turns from off to on
after a motion to ( ) coordinate is
made by jog operation.
Reset when alarm reset PB turns
on or power switches from off to on.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMr-j2s-*aMr-j2s- a seriesMr-j2s-20a

Table of Contents