Mitsubishi Electric MELSERVO MR-J2S- A Instruction Manual page 92

General-purpose ac servo general-purpose interface servo amplifier
Table of Contents

Advertisement

3. SIGNALS AND WIRING
(7) Source input interface
When using the input interface of source type, all Dl-1 input signals are of source type. Source output
cannot be provided.
For use of internal power supply
(Note)
For a transistor
Approx. 5mA
Switch
TR
V
1.0V
CES
I
100 A
CEO
Note. This also applies to the use of the external power supply.
When using the input interface of source type, all Dl-1 input signals are of source type. Source output
cannot be provided.
For 11kW or more, the source input interface cannot be used with the internal power supply. Always use
the external power supply.
Note. The jumper, which is shown black for the convenience of explanation, is actually white.
Servo amplifier
SG
R: Approx. 4.7
COM
SON,
etc.
24VDC
VDD
MITSUBISHI
For use of external power supply
Switch
24VDC
200mA or more
CON2
JP11
CON2
Jumper
For sink input (factory setting)
JP11
3 - 45
Servo amplifier
SG
R: Approx. 4.7
COM
SON,etc.
CON2
(Note)
JP11
Jumper
For source input
(Note)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMr-j2s-*aMr-j2s- a seriesMr-j2s-20a

Table of Contents