Mitsubishi Electric MELSERVO MR-J2S- A Instruction Manual page 67

General-purpose ac servo general-purpose interface servo amplifier
Table of Contents

Advertisement

3. SIGNALS AND WIRING
(2) Output signals
Signal
Symbol
Trouble
ALM
Dynamic brake
DB
interlock
Ready
RD
In position
INP
Speed reached
SA
Limiting speed
VLC
Limiting torque
TLC
Zero speed
ZSP
Electromagnetic
MBR
brake interlock
Warning
WNG
Battery warning
BWNG
Connec-
tor pin
No.
CN1B
ALM turns off when power is switched off or the protective circuit
18
is activated to shut off the base circuit.
Without alarm occurring, ALM turns on within about 1s after
power-on.
This signal can be used with the 11kW or more servo amplifier.
When using this signal, set " 1
When the dynamic brake is operated, DB turns off. (Refer to
Section 13.1.4.)
CN1A
RD turns on when the servo is switched on and the servo
19
amplifier is ready to operate.
CN1A
INP turns on when the number of droop pulses is in the preset in-
18
position range. The in-position range can be changed using
parameter No. 5.
When the in-position range is increased, INP-SG may be kept
connected during low-speed rotation.
SA turns off when servo on (SON) turns off or the servomotor
speed has not reached the preset speed with both forward rotation
start (ST1) and reverse rotation start (ST2) turned off. SA turns
on when the servomotor speed has nearly reached the preset
speed. When the preset speed is 20r/min or less, SA always turns
on.
CN1B
VLC turns on when speed reaches the value limited using any of
6
the internal speed limits 1 to 7 (parameter No. 8 to 10, 72 to 75)
or the analog speed limit (VLA) in the torque control mode.
VLC turns off when servo on (SON) turns off.
TLC turns on when the torque generated reaches the value set to
the internal torque limit 1 (parameter No. 28) or analog torque
limit (TLA).
CN1B
ZSP turns on when the servo motor speed is zero speed (50r/min)
19
or less. Zero speed can be changed using parameter No. 24.
CN1B
Set "
1 " in parameter No. 1 to use this parameter. Note that
ZSP will be unusable.
19
MBR turns off when the servo is switched off or an alarm occurs.
To use this signal, assign the connector pin for output using
parameter No.49. The old signal before assignment will be
unusable.
When warning has occurred, WNG turns on.
When there is no warning, WNG turns off within about 1s after
power-on.
To use this signal, assign the connector pin for output using
parameter No.49. The old signal before assignment will be
unusable.
BWNG turns on when battery cable breakage warning (AL. 92) or
battery warning (AL. 9F) has occurred.
When there is no battery warning, BWNG turns off within about
1s after power-on.
Functions/Applications
" in parameter No. 1.
3 - 20
Control
I/O
mode
division
P
S
T
DO-1
DO-1
DO-1
DO-1
DO-1
DO-1
DO-1
DO-1
DO-1
DO-1
DO-1