[Al. 011_Switch Setting Error] - Mitsubishi Electric Melservo-J5 MR-J5 Series User Manual

Troubleshooting
Hide thumbs Also See for Melservo-J5 MR-J5 Series:
Table of Contents

Advertisement

[AL. 011_Switch setting error]

• The setting of the DIP switch is incorrect.
• The setting of the rotary switch is incorrect.
[AL. 011.1_Rotary switch setting error]
Cause
1.
Each selected network has its settable range,
and the values set with the rotary switches
(SW1/SW2) were set out of the range.
[AL. 011.2_Disabling control axis setting error]
Cause
1.
The setting of the disabling control axis switch
is incorrect.
1 SERVO AMPLIFIER TROUBLESHOOTING
14
1.3 Handling methods for alarms/warnings
Check/action method
Check the settings of the rotary switches (SW1/SW2).
When the value set with the rotary switch and the actual value do not match,
the servo amplifier may be malfunctioning. Replace the servo amplifier.
Specifications on the setting of the rotary switches vary depending on each
network.
Refer to "Switch setting and display of the servo amplifier" in the following
manual.
MR-J5-G/MR-J5W-G User's Manual (Introduction)
Check/action method
Check the setting of the disabling control axis switch.
Refer to "Switch setting and display of the servo amplifier" in the following
manual.
MR-J5-G/MR-J5W-G User's Manual (Introduction)
If the above case does not apply, the servo amplifier may be malfunctioning.
Replace the servo amplifier.
Model
[G]
[WG]
Model
[WG]

Advertisement

Table of Contents
loading

Table of Contents