13. OPTIONS AND AUXILIARY EQUIPMENT

13.1.2 Brake unit

The brake unit is the integration of the regenerative control and resistor and is connected to the bus
(across P-N) of the servo amplifier. As compared to the MR-RB regenerative brake option, the brake unit
can return larger power. Hence, use the this brake unit when the MR-RB cannot provide sufficient
regenerative brake capability.
When using the brake unit, set "01
(1) Selection
Brake unit
Resistor unit
FR-BU-15K
FR-BR-15K
FR-BU-30K
FR-BR-30K
FR-BU-55K
FR-BR-55K
(2) Connection example
No-fuse breaker
NFB
Power supply
3-phase
200 to 300VAC
Note 1. Make up the external sequence to switch the power off when an alarm occurs or when the thermal relay is actuated.
2. When using servo amplifiers of 5kW and 7kW, always remove the lead of built-in regenerative brake resistor connected to P
terminal and C terminal.
3. When using servo ampliflers of 11kw to 22kw, always connect P-P
refer to Section 13.2.4
POINT
The brake unit and resistor unit of other than 200V class are not
applicable to the servo amplifier.
The brake unit and resistor unit of the same capacity must be combined.
The units of different capacities may result in damage.
The brake unit and resistor unit must be installed on a vertical surface in
the vertical direction. If they are installed in the horizontal direction or on
a horizontal surface, a heat dissipation effect reduces.
The temperature of the resistor unit casing rises to higher than 100
(212 ). Do not cause cables and combustibles to make contact with the
casing.
" in parameter No.0.
Permissible Continuous
Power [kw]
0.99
1.99
3.91
Servo amplifer
(Note3)
P
1
(Note2)
MC
P
L
1
C
L
2
L
N
3
L
11
L
21
Max. Instantaneous
Power [kw]
16.5
33.4
66.8
PR
FR-BU brake unit
.(Factory-wired.) When using the power factor improving DC reactor,
1
13 - 10
Applicable Servo Amplifier
MR-J2S-500A
MR-J2S-700A
MR-J2S-11KA
MR-J2S-15KA
MR-J2S-22KA
PR
P
(Note1)
HA
Alarm
HB
output
HC
FR-BR resistor unit
(Note1)
TH1
TH2
THS

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j2-super seriesMr-j2s-*aMr-j2s- a seriesMr-j2s-20a

Table of Contents