5. PARAMETERS

5.2.2 Analog monitor

The servo status can be output to two channels in terms of voltage. The servo status can be monitored
using an ammeter.
(1) Setting
Change the following digits of parameter No.17:
Parameters No.31 and 32 can be used to set the offset voltages to the analog output voltages. The setting
range is between
999 and 999mV.
Parameter No.
31
32
Parameter No. 17
0
0
Used to set the offset voltage for the analog monitor 1 (MO1).
Used to set the offset voltage for the analog monitor 2 (MO2)
output.
Analog monitor (MO1) output selection
(Signal output to across MO1-LG)
Analog monitor (MO2) output selection
(Signal output to across MO2-LG)
Description
5 - 30
Setting range [mV]
999 to 999