Td Sens Init Ok?; Force Tnr Supply:exe - Ricoh D117 Service Manual

Hide thumbs Also See for D117:
Table of Contents

Advertisement

Main SP Tables-3
3031

[TD Sens Init OK?]

001 From Left:YMCK
3050

[Force Tnr Supply:Exe]

001 Execute:ALL
002 Execute:Col
003 Execute:K
004 Execute:C
005 Execute:M
006 Execute:Y
021 Supply Quantity:K
022 Supply Quantity:C
023 Supply Quantity:M
024 Supply Quantity:Y
031 ON Time
032 OFF Time
033 RepeatCount
D117/D118
Displays the execution result of TD
*ENG
sensor initialization.
[0 to 9999 / - / 1/step]
[- / - / -]
ENG
[Execute]
[- / - / -]
ENG
[Execute]
[- / - / -]
ENG
[Execute]
[- / - / -]
ENG
[Execute]
[- / - / -]
ENG
[Execute]
[- / - / -]
ENG
[Execute]
*ENG
*ENG
[0.0 to 5.0 / 0.5 / 0.1wt%/step]
*ENG
*ENG
*ENG
[10 to 1000 / 200 / 1msec/step]
*ENG
[0 to 1000 / 100 / 1msec/step]
*ENG
[0 to 255 / 8 / 1times/step]