Main SP Tables-1
1113

[Curl Correction]

Execute Pattern
001
Selects the curl correction type.
Humidity:Threshold:M-humid *ENG
002
Specifies the threshold between low and middle humidity.
Humidity:Threshold:H-humid *ENG
003
Specifies the threshold between middle and high humidity.
Permit
Temp.:Delta:Press:M-humid
004
Specifies the threshold temperature for the curl control in middle humidity.
Permit
Temp.:Delta:Press:H-humid
005
Specifies the threshold temperature for the curl control in high humidity.
CPM:M-humid
008
Specifies the CPM ratio of the decurl control against to the normal operation in
middle humidity.
CPM:H-humid
009
Specifies the CPM ratio of the decurl control against to the normal operation in
high humidity.
D117/D118
*ENG
[0 or 1 / 0:OFF / 1/step]
[0 to 100 / 1 / 1 %/step]
[0 to 100 / 65 / 1 %/step]
*ENG
[0 to 200 / 60 / 1deg/step]
*ENG
[0 to 200 / 50 / 1deg/step]
*ENG
[0 to 100 / 50 / 1%/step]
*ENG
[0 to 100 / 40 / 1%/step]
3-14
SM Appendix