System Switch 19 (Sp No. 1-101-026); System Switch 1A (Sp No. 1-101-027) - Ricoh D117 Service Manual

Hide thumbs Also See for D117:
Table of Contents

Advertisement

Bit Switches
No
Function
0-5
Not used
Extended scanner page
memory after memory option is
6
installed
0: Disabled
1: Enabled
Special Original mode
7
0: Disabled
1: Enabled
No
Function
0
LS RX memory capacity
to
threshold setting
7
00-FF (0-1020 Kbyte: Hex)
System Switch 1B - Not used (do not change these settings)
System Switch 1C - Not used (do not change these settings)
D649

System Switch 19 (SP No. 1-101-026)

Do not change the settings.
0: After installing the memory expansion option,
the scanner page memory is extended to 4 MB
from 2 MB.
1: If this bit is set to 1 after installing the
memory expansion option, the scanner page
memory is extended to 12 MB. But the SAF
memory decreases to 18 MB.
1: If the customer frequently wishes to transmit
a form or letterhead which has a colored or
printed background, change this bit to "1".
"Original 1" and "Original 2" can be selected in
addition to the "Text", "Text/Photo" and "Photo"
modes.

System Switch 1A (SP No. 1-101-027)

Sets the value to x4KB. When the amount of
available memory drops below this setting, RX
documents are printed to conserve memory.
Initial setting 0x80 (512 KB)
NOTE: If a customer wants available memory
size larger, decrease this threshold.