Registration Correction; Magnification Adjustment - Ricoh D117 Service Manual

Hide thumbs Also See for D117:
Table of Contents

Advertisement

Main SP Tables-2
028 Average Coverage:4:C
029 Average Coverage:4:M
030 Average Coverage:4:Y
031 Mode Counter:K
032 Mode Counter:CMY
033 Execution Interval: Setting:5
034 High Coverage Threshold:5
035 Application Time:5

[Registration Correction]

These values are the parameters for the automatic line position adjustment
2101
and are adjusted at the factory. However, you must input a value for
SP2101-001 after replacing the laser optics housing unit. The value should be
provided with the new laser optics housing unit.
001 Color Main Dot: Bk
002 Color Main Dot: Ma
003 Color Main Dot: Cy
004 Color Main Dot: Ye
005 Color Sub Line: Bk
006 Color Sub Line: Ma
007 Color Sub Line: Cy
008 Color Sub Line: Ye

[Magnification Adjustment]

These values are the parameters for the automatic line position adjustment
2102
and are adjusted at the factory. These SPs must be input only when a new
laser unit is installed.
D117/D118
*ENG
[0.00 to 100.00 / 0.05 / 0.01%/step]
*ENG
[0.00 to 100.00 / 0.05 / 0.01%/step]
*ENG
[0.00 to 100.00 / 0.05 / 0.01%/step]
*ENG
[0 to 999 / - / 1page/step]
*ENG
[0 to 999 / - / 1page/step]
*ENG
[0 to 999 / 20 1page/step]
*ENG
[60.00 to 100.00 / 60.00 / 0.01%/step]
*ENG
[0 to 99 / 3 / 1sec/step]
*ENG
*ENG
[–512 to 511 / 0 / 1dot/step]
*ENG
*ENG
*ENG
*ENG
[–16384 to 16383 / 0 / 1line/step]
*ENG
*ENG
3-72
SM Appendix

Advertisement

Table of Contents
loading

This manual is also suitable for:

D118Mp c305spMp c305spf

Table of Contents