Address
Tone attenuation value difference
between high frequency tone and
680553
low frequency tone in DTMF
signals
PSTN: DTMF tone attenuation
680554
level after dialling
ISDN: DTMF tone attenuation
680555
level after dialling
680556 Not
used
Time between 68054Dh (NCU
680557
parameter 14) and 68054Eh (NCU
parameter 15)
680558 Not
used
Grounding time (ground start
680559
mode)
68055A
Break time (flash start mode)
International dial access code
68055B
(High)
International dial access code
68055C
(Low)
SM
Function
-dBm x 0.5
-N x 0.5
–3.5 dBm
-dBm x 0.5
-
1 ms
-
20 ms
1 ms
BCD
129
Unit
Remarks
SP2-103-021
(parameter 20).
The setting must be less
than –5dBm, and should
not exceed the setting at
680552h above.
See Note 5.
SP2-103-022
(parameter 21). See
Note 5.
See Note 5
Do not change the
settings.
This parameter takes
effect when the country
code is set to France.
Do not change the
setting.
The Gs relay is closed
for this interval.
The OHDI relay is open
for this interval.
For a code of 100:
68055B - F1
68055C - 00
NCU Parameters