Main SP Tables-3
3330
[ID.Sens Coef :Disp]
001 K2(Latest)
011 K5(Latest)
3331
[ID.Sens Coef :Set]
001 K2: Upp Limit Corr
002 K2: Lwr Limit Corr
003 K2: Upp/Lwr Limit Coef1
004 Kn: Lower
005 Kn: Upper
006 K5: Upper
007 K5: Lower
008 K5: Target Point
009 K5: Target Voltage
D117/D118
*ENG
Displays the latest value for the sensitivity
correction coefficient (K2 or K5) of ID
sensor.
*ENG
[0.0000 to 5.0000 / - / 0.0001/step]
*ENG
[-0.20 to 0.40 / 0.07 / 0.01/step]
*ENG
[-0.40 to 0.20 / -0.07 / 0.01/step]
*ENG
[0.00 to 1.00 / 0.00 / 0.01/step]
Sets the upper limit of valid range of
normalized value for normal reflection
*ENG
light using the sensitivity correction (K5).
[0.00 to 1.00 / 1.00 / 0.01/step]
Sets the lower limit of valid range of
normalized value for normal reflection
*ENG
light using the sensitivity correction (K5).
[0.00 to 1.00 / 0.10 / 0.01/step]
Sets the upper limit of the sensitivity
*ENG
correction coefficient (K5).
[0.00 to 10.00 / 5.00 / 0.01/step]
Sets the lower limit of the sensitivity
*ENG
correction coefficient (K5).
[0.00 to 1.00 / 0.50 / 0.01/step]
Sets correction point (Kn) for sensitivity
*ENG
correction coefficient (K5).
[0.00 to 1.00 / 0.15 / 0.01/step]
Sets correction point (delta
Vsp_dif_Dash) for sensitivity correction
*ENG
coefficient (K5).
[0.00 to 5.00 / 1.63 / 0.01V/step]