[Execution Interval]

Charge AC Control
001
Counter
3600

[Select ProCon]

001 Potential Control
002 LD Control
003 TC Adj. Mode
004 ACC Before ProCon
006 Pattern Cal. Method
D117/D118
*ENG
[0 to 2000 / 500 / 1page/step]
Sets the potential control mode.
*ENG
[0 or 1 / 1:CONTROL / 1/step]
0:FIXED, 1:CONTROL
Sets the LD control mode.
*ENG
[0 or 1 / 1:ON / 1/step]
0:OFF, 1:ON
Sets the execution timing for toner
density adjustment process control.
[0 to 2 / 1 / 1/step]
*ENG
0:Do Not Execute
1:1st Power On
2:1st Power On & Job End
Selects the performance same as the
process control executed before ACC.
[0 to 2 / 2 / 1/step]
*ENG
0:Not Execute
1:Process Control
2:TC Control
[0 to 2 / 2 / 1/step]
0:FIXED
*ENG
1:INITIALIZED
2:CALCULATED