Dev Agitating Time :Set - Ricoh D117 Service Manual

Hide thumbs Also See for D117:
Table of Contents

Advertisement

014 Corr(Mid):FC
3539

[Dev Agitating Time :Set]

001 Time
010 ON/OFF(by AbsHum)
011 by AbsHum:1
012 by AbsHum:2
013 by AbsHum:3
014 by AbsHum:4
015 by AbsHum:5
016 by AbsHum:6
021 AbsHum Threshold:1
022 AbsHum Threshold:2
023 AbsHum Threshold:3
024 AbsHum Threshold:4
025 AbsHum Threshold:5
ON/OFF(by Non-use
030
Time)
031 by Non-use Time:1
032 by Non-use Time:2
SM Appendix
Sets the correcting coefficient (Mid) for
*ENG
job end process control.
[0.00 to 1.00 / 1.00 / 0.01/step]
Sets the developer agitating time.
*ENG
[0 to 3000 / 10 / 1sec/step]
Sets on/off for absolute humidity
correction of the developer agitating time.
*ENG
[0 or 1 / 1:ON / 1/step]
0:OFF, 1:ON
*ENG
[0 to 3000 / 0 / 1sec/step]
*ENG
[0 to 3000 / 0 / 1sec/step]
*ENG
[0 to 3000 / 5 / 1sec/step]
*ENG
[0 to 3000 / 5 / 1sec/step]
*ENG
[0 to 3000 / 5 / 1sec/step]
*ENG
[0 to 3000 / 5 / 1sec/step]
*ENG
[0.0 to 65.0 / 4.0 / 0.1g/m^3/step]
*ENG
[0.0 to 65.0 / 8.0 / 0.1g/m^3/step]
*ENG
[0.0 to 65.0 / 12.0 / 0.1g/m^3/step]
*ENG
[0.0 to 65.0 / 16.0 / 0.1g/m^3/step]
*ENG
[0.0 to 65.0 / 24.0 / 0.1g/m3/step]
Sets on/off for non-use time correction of
the developer agitating time.
*ENG
[0 or 1 / 1:ON / 1/step]
0:OFF, 1:ON
*ENG
[0 to 3000 / 0 / 1sec/step]
*ENG
3-223
Main SP Tables-3
D117/D118