Heat Storage Status; Target Temp. Correction; Heat Storage Fb Control - Ricoh D117 Service Manual

Hide thumbs Also See for D117:
Table of Contents

Advertisement

[Heat Storage Status]

1114
Sets the threshold for fusing temperature correction to compensate for heat
accumulated on the pressure roller.
001 Temp.:Threshold:Press
002 Temp.:Threshold:Atmosphere *ENG

[Target Temp. Correction]

1115
Corrects the temperature based on the difference in the target temperatures
of the end of the hot roller.
001 Temp.:Delta:End
1116

[Heat Storage FB Control]

Execution mode
001
Sets the scope of application for FB control pf the heat accumulated on the
pressure roller.
Time Out
011
Sets the time between paper feed starting and temperature correction
starting.
021 to
Sets the time until the pressure temperature is acquired from F GATE with
026
normal speed or low speed.
021 Delay:Standard Speed:FC:1 *ENG
022 Delay:Standard Speed:FC:1 *ENG
025 Delay:Low Speed:FC:1
026 Delay:Low Speed:FC:1
031 Delay:Standard Speed:FC:2 *ENG
032 Delay:Standard Speed:FC:2 *ENG
035 Delay:Low Speed:FC:2
SM Appendix
*ENG
[0 to 200 / 80 / 1 deg/step]
[0 to 200 / 80 / 1 deg/step]
*ENG
-
*ENG
[0 to 2 / 0:OFF / 1/step]
*ENG
[0 to 500 / 10 / 1sec/step]
[0 to 20000 / 3862 / 1msec/step]
[0 to 20000 / 2712 / 1msec/step]
*ENG
[0 to 20000 / 8093 / 1msec/step]
*ENG
[0 to 20000 / 5783 / 1msec/step]
[0 to 20000 / 3862 / 1msec/step]
[0 to 20000 / 2712 / 1msec/step]
*ENG
[0 to 20000 / 8093 / 1msec/step]
3-15
Main SP Tables-1