Fan Cooling Time Set; Fan Start Time Set - Ricoh D117 Service Manual

Hide thumbs Also See for D117:
Table of Contents

Advertisement

Main SP Tables-1
Paper Tray2: Minimum
049
Interval: Thick
Paper Tray3 Minimum
050
Interval: Plain
Paper Tray3 Minimum
051
Interval: Middle Thick
Paper Tray3 Minimum
052
Interval: Thick

[Fan Cooling Time Set]

1950
Adjust the rotation time for each fan motor after a job end.
001 Imaging Cooling Fan
002 Fusing Exit Fan
003 PSU Fan
004 Writing Cooling Fan

[Fan Start Time Set]

1951
Adjust the start time for each fan motor after a job end.
001 Imaging Cooling Fan
002 Fusing Exit Fan
003 PSU Fan
004 Writing Cooling Fan
D117/D118
*ENG
[-10 to 10 / 0 / 1mm/step]
*ENG
[-10 to 10 / 0 / 1mm/step]
*ENG
[-10 to 10 / 0 / 1mm/step]
*ENG
[-10 to 10 / 0 / 1mm/step]
*ENG
[0 to 600 / 0 / 1sec/step]
*ENG
[0 to 600 / 10 / 1sec/step]
*ENG
[0 to 600 / 0 / 1sec/step]
*ENG
[0 to 600 / 0 / 1sec/step]
*ENG
[0 to 120 / 0 / 1sec/step]
*ENG
[0 to 120 / 0 / 1sec/step]
*ENG
[0 to 120 / 0 / 1sec/step]
*ENG
[0 to 120 / 0 / 1sec/step]