Ricoh D117 Service Manual page 1084

Hide thumbs Also See for D117:
Table of Contents

Advertisement

Code
Meaning
Counter overflow error of
2-22
JBIG chip
JBIG compression or
2-23
reconstruction error
2-24 JBIG
ASIC error
JBIG data reconstruction
2-25
error (BIH error)
JBIG data reconstruction
2-26
error (Float marker error)
JBIG data reconstruction
2-27
error (End marker error)
JBIG data reconstruction
2-28
error (Timeout)
JBIG trailing edge maker
2-29
error
The machine resets itself
2-50
for a fatal FCU system
error
The machine resets itself
2-51
because of a fatal
communication error
Snd msg() in the manual
task is an error because
2-53
the mailbox for the
operation task is full.
4-01
Line current was cut
SM
Suggested Cause/Action
If this error occurs frequently, change the
settings for resolution, paper size and
compression type.
Turn off the machine, then turn it back on.
Turn off the machine, then turn it back on.
JBIG data error
Check the sender's JBIG function.
Update the MBU ROM.
FCU
defective
Check the destination device.
If this is frequent, update the ROM, or replace
the FCU.
If this is frequent, update the ROM, or replace
the FCU.
The user did the same operation many times,
and this gave too much load to the machine.
Check the line connector.
Check for line problems.
Replace
the FCU.