Communication Switch 1B (Sp No. 1-104-028); Communication Switch 1C (Sp No. 1-104-029) - Ricoh D117 Service Manual

Hide thumbs Also See for D117:
Table of Contents

Advertisement

Communication Switch 1B (SP No. 1-104-028)

No
Function
Extension access code (0 to 7)
to turn V.8 protocol On/Off
0-7
0: On
1: Off

Communication Switch 1C (SP No. 1-104-029)

No
Function
Extension access code (8 and
9) to turn V.8 protocol On/Off
0-1
0: On
1: Off
2-7
Not used
Communication Switch 1D - Not used (do not change the settings)
Communication Switch 1E - Not used (do not change the settings)
Communication Switch 1F - Not used (do not change the settings)
SM
Comments
If the PABX does not support V.8/V.34 protocol
procedure, set this bit to "1" to disable V.8.
Example: If "0" is the PSTN access code, set bit 0
to 1. When the machine detects "0" as the first
dialed number, it automatically disables V.8
protocol. (Alternatively, if "3" is the PSTN access
code, set bit 3 to 1.)
Comments
Refer to communication switch 1B.
Example: If "8" is the PSTN access code, set bit 0
to 1. When the machine detects "8" as the first
dialed number, it automatically disables V.8
protocol. (If "9" is the PSTN access code, use bit
1.)
Do not change the settings.