Access Point; Line Connecting; Modem Serial No. - Ricoh D117 Service Manual

Hide thumbs Also See for D117:
Table of Contents

Advertisement

Main SP Tables-5
When the Call Center calls out to an embedded RCG-M modem, it sends a
repeating ID tone (*#1#). This SP sets the time the line remains open to send
these ID tones after the number of the embedded RCG-M modem is dialed up
and connected.
The actual amount of time is this setting x 2 sec. For example, if you set "2"
the line will remain open for 4 sec.

Access Point

This is the number of the dial-up access point for RCG-M. If no setting is done
for this SP code, then a preset value (determined by the country selected) is
163
used.
Default: 0
Allowed: Up to 16 alphanumeric characters

Line Connecting

This SP sets the connection conditions for the customer. This setting
dedicates the line to RCG-M only, or sets the line for sharing between RCG-M
164
and a fax unit.
If this setting is changed, the copier must be cycled off and on.
SP5816 187 determines whether the off-hook button can be used to
interrupt a RCG-M transmission in progress to open the line for fax
transaction.

Modem Serial No.

173
This SP displays the serial number registered for the RCG-M.
D117/D118
*CTL
[up to 16 / 0 / 1/step]
[0 to 1 / 0 / 1/step]
*CTL
0: Sharing Fax
1: No Sharing Fax
*CTL
[- / - / -]
3-346
SM Appendix

Advertisement

Table of Contents
loading

This manual is also suitable for:

D118Mp c305spMp c305spf

Table of Contents