IMPORTANT: Vent cap location must be in compliance with guidelines on page 20 of this manual.

VERTICAL TERMINATIONS

Follow vent pipe manufacturer‟s installation instructions for vertical terminations. A minimum 1" (25mm) clearance on all sides of vertical
vent pipe must be maintained.

HORIZONTAL TERMINATIONS

Follow vent pipe manufacturer‟s installation instructions for horizontal terminations. Include required 3" (76mm) top clearance (at wall pass
-thru) and 1" (25mm) sides and bottom clearances for approved rigid vent systems.
IMPORTANT: KOZY HEAT WALL THIMBLE PASS-THRU (#800-WPT or #800-WPT2) MUST BE USED ON ALL HORIZONTAL VENT RUNS.
FOLLOW INSTRUCTIONS ON PAGE 17 OF THIS INSTALLATION MANUAL.
IMPORTANT: THE HORIZONTAL VENT HEAT SHIELD INCLUDED WITH THIS FIREPLACE MUST BE INSTALLED WHEN USING A 90-
DEGREE ELBOW DIRECTLY OFF TOP OF UNIT TO HORIZONTALLY POSITION VENT SYSTEM.
CAUTION: Cold air transfer area. The surrounding fireplace chase must comply with all clearances as outlined in this manual and be
constructed in compliance with local building codes. Outside walls should be insulated to prevent cold air from entering room.
CAUTION: Due to high temperatures, this fireplace should be located out of traffic areas and away from furniture and draperies.
VENT PIPE TOP (A)
RIGID PIPE
41-1/4" (1048mm)
Figure 9a
FRAMING
MINIMUM HORIZONTAL FRAMING DIMENSIONS
FRAMED OPENING TOP (B)
44-1/4" (1124mm)
TERMINATION WIDTH (W)
12-1/2" (318mm)
IMPORTANT: Header must be positioned „up‟ to maintain proper
clearances from vent system to combustibles.
32-5/8"
(829mm)
19-3/4"
(502mm)
PAGE 9
TERMINATION HEIGHT (H)
10-7/8" (276mm)