Framing; Wall Enclosure Rough Opening - kozy heat Two Harbors 55616 Installation And Operation Manual

Table of Contents

Advertisement

WALL ROUGH OPENING
IMPORTANT: Framing dimensions should allow for wall covering thickness and fireplace facing materials.
If using a hearth, adjust rough opening size as necessary to maintain at least minimum clearance requirements.
IMPORTANT: Non-combustible material man be applied around (but not directly to) fireplace face.
(
APPLIES TO BOTH HORIZONTAL AND VERTICAL VENTING TERMINATIONS)
32-5/8" (829mm) High* x 19-3/4"(502mm) Wide x 14-7/8" (378mm) Deep.
* Header must be in the „up‟ position to maintain proper clearances from vent system to combustibles.
MINIMUM ENCLOSURE HEIGHT: 47" (1.19m) from base of fireplace.
WARNING: Install fireplace on hard metal or wood surface extending full width and depth of fireplace.
Minimum platform size: 19-3/4" (502mm) wide x 14-7/8" (378mm) deep.
FIRE HAZARD: Do NOT install directly on carpeting, vinyl, or any combustible material other than wood.
Figure 8a
Determine exact position of fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a manner
that vent termination will be placed between two studs, eliminating the need for additional framing.
If masonry is to be used (optional), prepare necessary foundation for the masonry load. When masonry construction is being used, a lintel
must be used over top of fireplace to support the added weight.
Build hearth to desired size and height. If a hearth extension is desired, combustible material may be used. If carpeting or other combustible
flooring is desired in front of fireplace, fireplace bottom must level or above flooring material level.

FRAMING

IMPORTANT: Header must be positioned „up‟ to maintain proper
clearances from vent system to combustibles.
47"
(1.19m)
19-3/4"
(502mm)
PAGE 8
14-7/8"
(378 mm)