kozy heat Two Harbors 55616 Installation And Operation Manual page 27

Table of Contents

Advertisement

LIGHTING AND SHUTDOWN (cont.)
LIGHTING
1.
Set thermostat to lowest setting, if installed.
2.
Turn off all electrical power to appliance. (Fan).
3.
Open lower grill to access gas valve & controls.
A. Push gas control knob in slightly and turn clockwise to OFF. Wait five (5)
minutes to allow any gas that may have accumulated inside firebox to escape.
If you then smell gas, STOP! Follow safety information on previous page and
front cover of this installation manual. If you don‟t smell gas, go to next step.
NOTE: Gas control knob cannot be turned from PILOT to OFF unless knob is
pushed in slightly. Do not force.
B.
Locate pilot - follow metal tube from gas control. (Located inside combustion
chamber).
C.
Push gas valve control knob on in slightly and turn counterclockwise to
PILOT. Push valve knob in and hold while repeatedly pressing piezo igniter
button until pilot is lit while continuing to hold in gas control knob.
D. Hold gas control knob in for one (1) minute after pilot is lit.
Release gas control knob. If pilot goes out, repeat steps C-D.
When pilot is lit, proceed to step E.
CAUTION: If knob does not pop up when released, stop and immediately call
your service technician or gas supplier. If pilot will not stay lit after
several tries, turn gas control knob to OFF and call your service
technician or gas supplier.
E.
Push gas control knob in slightly and turn counterclockwise to ON. The burner
can now be turned ON by depressing ON/OFF rocker switch located beside
valve, or wall switch, OR by setting thermostat or remote control to desired
setting.
F.
Turn on all electric power to appliance (if applicable).
NOTE: When fireplace is initially lit, condensation will appear on glass; this is
normal in all gas fireplaces and will disappear after several minutes.
TURN BURNER OFF
G. To turn burner OFF, depress ON/OFF rocker switch to OFF, flip off wall
switch or adjust setting on thermostat or remote control.
NOTE: The pilot will stay lit.
TURN PILOT OFF
H. Turn pilot off by pushing in and turning gas control knob to OFF. DO NOT
FORCE.
NOTE: This control valve has an interlock device. If pilot has been turned off, it
cannot be relit until thermocouple has cooled, (approx. 60 seconds).
ADJUSTING FLAME HEIGHT
The gas control valve has a HI/LO flame adjustment knob designed to allow you to
tailor the look and heat output of your fireplace. Adjust by turning knob.
A
B
C
D-E
G-H
Figure 26a
PAGE 26
5 MINUTES
PILOT
PILOT TUBE
1 MINUTE