Log Set Installation - kozy heat windom 56101 Installation And Operation Manual

Direct vent fireplace
Table of Contents

Advertisement

#WDM-50B LOG SET INSTALLATION
If installing optional brick refractory please do so now before installing log set. Follow instructions included with kit.
ATTENTION
If converting to LP (propane) gas do so now before installing log set. Follow instructions included with kit.
NOTE
Log numbers are located on bottom of each log. Refer to following instructions and illustrations for proper placement.
Do not place logs directly over burner port holes. Improper log placement may affect flame appearance and cause excessive
CAUTION
soot to build up on logs and glass.
Figure 22a
Align cutout in log #W5 over pilot assembly and slots in bottom of log over burner cover brackets. Press down slightly to secure.
NATURAL GAS MODELS: Position backsides of #W6 & #W7 logs up against burner tube.
Figure 22b
Randomly place „Klinkers" in this area. Do not place „Klinkers" directly on burner ports.
Use a steel or stiff bristle nylon brush to distribute Rock Wool Embers onto logs and burner.
W6
Position #W6 and #W7 logs onto burner center.
Position #W8, #W9, & #W10 logs, aligning to notches in base logs.
W8
W5
W7
W9
22
W10