Mantel Requirements; Framing; Wall Enclosure Rough Opening - kozy heat windom 56101 Installation And Operation Manual

Direct vent fireplace
Table of Contents

Advertisement

Figure 10a

WALL ENCLOSURE ROUGH OPENING

Applies to horizontal and vertical vent terminations: 32-1/4" (819mm) High x 36-1/2"(927mm) Wide x 11-1/4" (286mm) Deep.
Framing dimensions should allow for wall covering thickness and fireplace facing materials. If using a hearth, adjust rough
opening size as necessary to maintain at least minimum clearance requirements.
IMPORTANT
Non-combustible facing material may be applied over (but not directly to) fireplace face. This will prevent facing material from
falling off due to heat expansion. Do not obstruct the flow of ventilation air.
Provide adequate clearance in front of fireplace to operate lower grill, open and close optional decorative doors / full door faces,
NOTE
access components, installation of gas line, fan, etc.
Do not obstruct upper and lower grill openings. Room air enters through lower passage, is heated and exits through upper
WARNING
passage. Blocking these passages may result is overheating, creating a potentially hazardous situation.
Determine exact position of your fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a
manner that vent termination will be placed between two studs, eliminating the need for additional framing.
If masonry is to be used (optional), prepare foundation for the masonry load. When masonry construction is being used, lintel (#617) must
be used over top of fireplace to support the added weight.
Figure 10b

MANTEL REQUIREMENTS

FRAMING

32-1/4"
(819mm)
36-1/2"
(927mm)
11-1/4"
(286mm)
10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents