Horizontal sections require 1/4" (6mm) rise for every 12" (305mm) of travel.
NOTE
Page 17 has information on restrictor installation in conjunction with venting installation. Page 31 has information on restrictor
recommendations depending on burner flame appearance and instructions on installation after venting is completed.
CAUTION
This gas appliance must not be connected to or joined with any other chimney flue serving another appliance.
WARNING
A WALL PASS-THRU MUST BE USED ON ALL HORIZONTAL VENT RUNS.
MINIMUM HORIZONTAL VENTING (corner installations - NAT. gas only)
This minimum venting configuration is for use with NAT. gas only. See illustration at bottom of page for minimum corner
IMPORTANT
installation for LP gas. The illustration at bottom of page may also be used for a Nat. gas application if desired.
Figure 19a
MINIMUM HORIZONTAL VENTING (corner installations - L.P. gas )
TERMINATION CAP
6" (152mm)
90° ELBOW
Figure 19b
VENTING
TERMINATION CAP
6" (152mm)
45° ELBOW
May also be used for Nat. gas application if desired.