HEARTH EXTENSION REQUIREMENTS
Consider height of hearth finish material (stone, brick, etc.) when building fireplace platform. Bottom of fireplace must be level
NOTE
with finished hearth to allow for lower grill operation and proper fit of optional decorative full door faces.
Install fireplace on hard metal or wood surface extending the full width and depth of fireplace. Minimum platform size:
WARNING
36" (914mm) wide x 11" (610mm) deep.
Do NOT install directly on carpeting, vinyl, or any combustible material other than wood.
Build hearth to desired size and height. If a hearth extension is desired, combustible material may be used.

VERTICAL TERMINATIONS

Follow vent pipe manufacturer‟s installation instructions for vertical terminations. A minimum 1" (25mm) clearance on all sides of vertical
vent pipe must be maintained.

HORIZONTAL TERMINATIONS

Follow vent pipe manufacturer‟s installation instructions for horizontal terminations. Include the required 1-1/2" (38mm) top clearance (at
wall pass-thru) and 1" (25mm) sides and bottom clearances for approved rigid vent systems.
To achieve minimum venting requirements, a minimum of 26" (660mm) from floor or hearth the fireplace is setting on to top of
vent pipe is required.
IMPORTANT
Wall pass-thru required for all horizontal runs. Refer to vent manufacturers' to determine which pass-thru will work best for
your application and wall thickness.
Cold air transfer area. The surrounding fireplace chase must comply with all clearances as outlined in this manual and be
constructed in compliance with local building codes. Outside walls should be insulated to prevent cold air from entering room.
CAUTION
Due to high temperatures, this fireplace should be located out of traffic areas and away from furniture and draperies.
Vent cap location must be in compliance with the guidelines on page #20 of this manual.
Top of wall pass-thru
1-1/2" (38mm) clearance
W
26" (660mm) min.
to top of vent pipe
TYPICAL HORIZONTAL TERMINATION
Figure 11a
FRAMING
Refer to vent pipe manufacturer's instructions for
specific height (H) and width (W) framing dimensions.
H
Inside framing to stud wall
1-1/2" (38mm)
KOZY HEAT CORNER CABINET FRAMING
11
H
W
39" (991mm) to top
of framing