External Meters Display - Euphonix Max Air Manual

Hide thumbs Also See for Max Air:
Table of Contents

Advertisement

Euphonix Max Air Mixing Console Operations Manual
9.
Touch the
This places the first eight aux meters in the fifth bank.
10.
Repeat above steps for the Solo (in
lecting Main section E), and Control Room Meters (in Control Room).
The names that appear below the meters are the names assigned to the busses earlier.
Channel/Strip Metering
You can put channel meters along the top of the Touchscreen. There are 48 meter spaces
available along the top row, not including the right corner section. Note that there are
two options with the Channels and Strips buttons: channels are the actual logical chan-
nels, Strips are the physical position of the Strips on the console. If you set the meters to
show channels, these will not necessarily match what is on the actual console Strips.
When you select the Strips button you will notice that you can set the meters to look
at just the Main or the Swap or whatever is on the Fader by selecting the appropriate
tab below the bank of buttons. If you select Fader, the meters change when you press
the Swap button on a Strip. The meters will read the signal path that is being controlled
by the actual fader. Also note that the position of the meter point in a channel can be
individually set to one of seven positions, so it can meter pre- or post-fader, pre- or post-
EQ, etc. The position of the meter in the channel signal path can be set by selecting the
Super Channel Main Menu button, then the Setup button in the Process Order box to
the left.
3.5.3

External Meters Display

The optional External Meters Display allows the user to view up to 28 additional banks
of meters on an external display. An additional graphics card and 1280x1024 resolution-
capable display is required for this feature.
There are three display modes for the External Meters Display:
None -- only displays the Max Air logo.
3 Rows -- displays three 7-bank rows of meters
4 Rows -- displays four 7-bank rows of meters
To set up the External Meters Display, select Meters from the Main Menu. Select the
Setup tab and choose three or four rows of external meters. Select the Screen tab. Select
the Ext 1 tab. Configure the top 7 banks of meters, selecting what you want displayed
in each bank. (See page 85 to learn how to configure a meter bank.) These 7 banks will
appear as the first row of banks on the External Meter Display. Selecting the Ext 2, Ext
3 and Ext 4 tabs enable you to set up the second, third, and fourth rows of meter banks,
respectively.
You can also choose different colors for each meter bank. When the bank is highlighted,
select one of the colors from the column on the right side of the popup. The default color
is blue.
Select Range button in the Aux Busses view. Touch 1, then 8.
38
Quickstart to Common Tasks
Solo Bus), Program (in Main sections by se-

Advertisement