07
06
AMPMRLY
EXPBRST
AMPMRLY – Amp Mains Relay CTRL
= 0: Relay is open.
= 1: Relay is closed.
EXPBRST – Expansion Slot 1 Reset
= 0: Expansion Slot 1 is reset.
= 1: Expansion Slot 1 is out of reset.
EXPARST – Expansion Slot 0 Reset
= 0: Expansion Slot 0 is reset.
= 1: Expansion Slot 0 is out of reset.
ETRGEN1 – External Trigger 1 Enable
= 0: External Trigger 1 is inactive.
= 1: External Trigger 1 is active.
ETRGEN0 – External Trigger 0 Enable
= 0: External Trigger 0 is inactive.
= 1: External Trigger 0 is active.
DSPCRST – Format DSP Reset
= 0: CS494001 is in reset.
= 1: CS494001 is out of reset.
DSPBRST – SHARC U33 Reset
= 0: U33 is in reset.
= 1: U33 is out of reset.
DSPARST – SHARC U16 Reset
= 0: U16 is in reset.
= 1: U16 is out of reset.
Address == 0x00C00000
05
04
EXPARST
ETRGEN1
03
02
ETRGEN0
DSPCRST
01
00
DSPBRST
DSPARST