Fuser exit sensor removal

1.
Open the front cover.
Remove the right cover assembly. See
2.
3.
Remove the left cover. See
Disconnect the two-wire fuser cable (A) from the LVPS.
4.
Note: You do not have to extract the cable.
Remove the screw and grounding washer (B) on the right side of the frame.
5.
Note: Be careful not to lose the grounding washer.
Disconnect the thermistor cables (C).
6.
"Right cover removal" on page