Lexmark X548 Series Service Manual page 224

Hide thumbs Also See for X548 Series:
Table of Contents

Advertisement

7525-63x
Disconnect the narrow medial sensor cable and remove the cable from the fuser frame. See
7.
media sensor flag removal" on page
Note: Observe the cable routing.
Unhook the springs (D) from both sides of the fuser.
8.
D
Rotate the fuser toward the front of the printer until the screw (E) can be accessed, and removed.
9.
Disconnect the cable (G) from the fuser exit sensor.
10.
11.
Remove the screw (F) securing the fuser exit sensor.
Remove the lower end of the sensor with a flat-blade screwdriver, and gently pull the sensor from the
12.
frame.
Service Manual
4-38
4-17.
E
E
"Narrow
D
F
G