Print quality—mottle (2–5mm speckles)
Keep running prints through, and the problem normally clears up. If the problem persists,
replace the developer cartridge.
Print quality—narrow vertical line
Step
Questions / actions
Replace the photoconductor unit. See
1
"Developer unit removal" on page
Print quality—random marks
Service tip: The primary cause of random marks is due to loose material moving around inside the printer and
attaching to the photoconductor unit, developer roll, or transfer belt.
Step
Questions / actions
1
Is there any loose or foreign material on the
imaging unit?
2
Is there any loose or foreign material on the
developer roll?
3
Is there any loose or foreign material on the
transfer belt?
Yes
Problem solved.
4-47.
Yes
Inspect the imaging unit by
looking at the individual
developers and
photoconductors. Clean or
replace the faulty unit. See
"Developer unit removal"
on page
4-47.
Replace the developer unit.
Replace the image transfer
unit. See
"Image transfer
unit (ITU) removal" on
page
4-43.
7525-63x
ABCDE
ABCDE
ABCDE
No
Replace the developer unit.
See
"Developer unit
removal" on page
4-47.
No
Go to step 2.
Go to step 3.
Contact your next level of
support.
Diagnostic information
2-51
Previous
Next
Go Back