Lexmark X548 Series Service Manual page 67

Hide thumbs Also See for X548 Series:
Table of Contents

Advertisement

Service error messages
Error code
964.xx Service
Emulation Error
975.xx Service
Standard Network
or
975.xx Service
Network Card x
976.xx Service
Standard Network
or
976.xx Service
Network Card x
979.xx Service
Standard Network
or
979.xx Service
Network Card x
982.xx Service
<device> Comm.
990.xx Service
<device>
Description
Download emulation cyclic redundancy
check (CRC) failure has occurred. A
checksum failure detected in the
emulation header or emulation file.
Network error—Unrecognizable
network port.
Unrecoverable software or error in
network or network port.
Flash parts failed while programming
the network port.
Communications error detected by the
specified device.
Note: <device> can be one of the
following:
• Duplex unit
• Tray 2
• Tray 3
This error message indicates that an
equipment check condition has
occurred in the specified device, but
the device is unable to identify the
exact component failure.
Note: <device> can be one of the
following:
• Duplex unit
• Tray 2
• Tray 3
Action
The following actions may be taken:
1. Disable the Download Emulation.
2. Program the download emulation into
the code overlay SIMM again.
3. If the problem is not resolved replace
the code overlay SIMM, and download
emulation again.
Replace the standard network card or the
card in the specified slot.
If unable to clear the error message, check
the following:
• If installed, check the RIP board for
correct installation.
• If correctly installed, replace the RIP
board.
See"RIP board removal" on
page
4-19.
Check the following:
• If installed, check the RIP board for
correct installation.
• If correctly installed, replace the RIP
board.
See"RIP board removal" on
page 4-19
Diagnostic information
7525-63x
Previous
Next
Go Back
2-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

X548deX548dte

Table of Contents