Programming
ACS/ANN-BUS FAULT
LCD_80F FAULT
NAC 1 DISABLE
NAC 2 DISABLE
NAC 3 DISABLE
NAC 4 DISABLE
CS CALC FAULT
CHARGER FAULT
OPTION CARD 1 FAULT
REMOTE SYNC FAULT
ZONE DISABLE
NAC_KEY_FLT
NO_DEVICES_INSTLLD
OFF_NORMAL_MESSAGE
24_HOUR_TEST
24 HOUR ABNORMAL TES
UPDOWN REQUEST
UPLOAD SUCCESS
DOWNLOAD SUCCESS
UPDOWN FAILURE
GENERAL_ALARM
GENERAL_SUPERVISORY
MNS OVERRIDE
AUDIO MESSAGE

Report Style

CENTRAL STATION
1=PRIMARY
2=SECONDARY
Pressing 3 while viewing Central Station Screen #2 will cause the Report Style display to toggle
3=REPORT STYLE POINT
between Point and Zone. Setting the Report Style to Point will program the DACT to report
Central Station Screen #2
individual point status to the Central Station. The control panel is capable of monitoring a total of
198 addressable devices. Setting the Report Style to Zone will program the DACT to report zone
status to the Central Station. The control panel is capable of monitoring a total of 99 individual
zones.
NOTES:
1. Detector Address 01 will be reported to the Central Station as Point 01, Detector Address 02
as Point 02, with reports continuing in a similar fashion all the way up to Detector Address 99
which will be reported as Point 99.
2. Module Address 01 will be reported to the Central Station as Point 160, Module Address 02 will
be reported to the Central Station as Point 161, with reports continuing in a similar fashion all the
way up to Module Address 99 which will be reported as Point 258.
ON BOARD DACT
1=SERVICE TERMINAL
The Supervised Phone Line feature allows the user to disable the supervision of Phone Line 2 by
2=CENTRAL STATION
3=SUPERV PHONE LINE
the DACT when using an alternate means of secondary transmission path. The factory default
On Board DACT Screen #2
setting is Phone Line 2 supervised.
Pressing 2 for Superv Phone Line while viewing Onboard DACT Screen 2 will cause the following
screen to be displayed:
Each press of the 1 key while viewing this screen will toggle the option between Supervise Phone
Line 2 Yes and No.
124
333
330
521
522
526
527
304
300
331
332
570
300
380
308
602
608
411
416
412
413
000
000
580
000
Table 3.11 Event Codes (Continued)
Supervised Phone Line
000
000
000
000
001
001
002
002
003
003
004
004
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
000
Message #
SUPERVISE PHONE LINE
1=PHONE LINE 2
YES
Supervised Phone Line Screen
MS-9200UDLS Series Manual — P/N 52750:H 4/14/2014
Master Programming Level
EM
EN
EM
EN
ET
ER
ET
ER
ET
ER
ET
ER
YF
YP
YQ
ET
ER
OU
OV
FB
FU
ET
ER
ET
ER
LB
LX
RP
RY
RB
RS
RS
RR
00
00
00
00
00
00
00
00

Advertisement