  • Page 2: Table Of Contents

    Table of Contents Control Panel Circuit Specifications..........................3 Accessories Circuit Specifications..........................4 Fire Alarm Equipment – Controls & Systems Tested to ANSI Standards By Factory Mutual ........4 Compatible Two-Wire Smoke Detectors ........................4 Various Manufacturers ............................4 Maximum Number of Detectors per Zone ........................6 System Sensor................................6 Fenwal..................................9 Fire•Lite Detectors..............................9...
  • Page 3: Control Panel Circuit Specifications

    Control Panel Circuit Specifications MP-12 MS-5012 Initiating Device Circuit Voltage: 8.6 - 12.2VDC Initiating Device Circuit Voltage: 8.6 - 13.5VDC Max Detector Circuit Standby Current: 2.0mA/circuit Max Detector Circuit Standby Current: 2.0mA/circuit Compatibility Identifier: "A" Compatibility Identifier: "A" NAC Power: Full Wave Rectified NAC Power: Full Wave Rectified MP-24 and MP242FC MS-5024 and MS-5024UD...
  • Page 4: Accessories Circuit Specifications

    MS-5UD-7(E), MS-10UD-7(E), MS-5UD-7C, MRP-2001(E), MRP-2002(E) MS-10UD-7C Initiating Device Circuit Voltage: 17.18 - 20.48 Initiating Device Circuit Voltage: 17.18 - 20.48 Max Detector Circuit Standby Current: 2.0mA/circuit Max Detector Circuit Standby Current: 2.0mA/circuit Compatibility Identifier: "A" Compatibility Identifier: "A" NAC Power: Filtered (Special Applicaion) NAC Power: Filtered (Special Applicaion) Accessories Circuit Specifications 411-UDAC...
  • Page 5 Fenwal PSD-7126 P6FE1 Photo / Thermal 70-201000-001 FEO1A 70-201000-002 FEO2A 70-201000-003 FEO3A 70-201000-005 FEO5A Fenwal PSD-7129 P9FE1 Duct 70-211002-000 D22FE1 Fire-Lite LPSD-12 HD-4 Photo BLP-12 HB-80 Fire-Lite LPSD-12 HD-4 Photo BLP-12-R HB-83 Simplex 2098-9201 HD-3 Photoelectric 2098-9211 HB-54 Simplex 2098-9202...
  • Page 6: Maximum Number Of Detectors Per Zone

    Maximum Number of Detectors per Zone When using two-wire smoke detectors containing supplementary relays or indicators, the operation of more than one detector per zone cannot be ensured. System Sensor System Sensor & Fenwal Detectors can be mixed or matched in any zone, provided maximum detector standby current per loop is not exceeded.
  • Page 7 System Sensor Detectors - continued: MS-4424 Base MS-5012 Model Number MS-4012 MS-4024 MS-4424B MS-4412B Model 411-UDAC MRP-4424 1100/D 1151 B401 / B110LP / B116LP 16 / 16 / N/A 16 / 16 / 1 15 / 15 / 1 16 / 16 / N/A 16 / 16 / N/A 1400 1451...
  • Page 8 System Sensor Detectors - continued: MS-2 MS-4 MS-5024 Base MS-5UD M-302 S200 Model Number MS-5024UD S1000 Model MS-10UD MMF-302 S2000 MS-5210UD MRP-2001 MRP-2002 2W-B 2WT-B 1100/D 1151 B401 / B110LP / B116LP 16 / 16 / 1 16/16/1 20 / 20 / 1 20 / 20 / 1 1400 1451...
  • Page 9: Fenwal

    Fenwal Fenwal & System Sensor Detectors can be mixed or matched in any zone, provided maximum detector standby current per loop is not exceeded. MS-4424 Detector Base MP-24 MS-124 MS-424A MS-4024 MS-4424B Model Number Model Number MRP-4424 CPD-7021 70-201000-001 70-201000-002 70-201000-003 70-201000-005 CPD-7021...
  • Page 10: Edwards Detectors

    Smoke Detector/Base Detector Type Current (mA) (mA) Fenwal CPD-7021 (w/70-201000-005 Base) Ionization 0.10 Fenwal PSD-7125 Photoelectric 0.10 Fenwal PSD-7126 (w/70-201000-005 Base) Photoelectric 0.10 Fire-Lite BLP-12-4W Base † Gentex 824 Photoelectric 0.50 † Gentex 824T Photoelectric 0.50 † Gentex 824CP Photoelectric 0.50...
  • Page 11: Notification Appliances

    Max Standby Alarm Current Smoke Detector/Base Detector Type Current (mA) (mA) † System Sensor DH400ACDCI Ionization Duct † System Sensor DH400ACDCP Photoelectric Duct System Sensor 1112/24/D Ionization 0.05 System Sensor 1424 Ionization 0.10 System Sensor 1451 (w/ B402B/B112LP Base) Ionization 0.10 System Sensor 2112/24ATR Photoelectric...
  • Page 12: System Sensor - 12Vdc

    System Sensor - 12VDC Use only 12VDC devices with 12 volt control panels. MODEL NUMBER & NOMENCLATURE (System Sensor) CH12/24 Electronic Chime/Sounder H12 SpectrAlert Horn MA-12/24D Electronic Sounder MA12/24EH Multi Alert Horn with Mechanical Tone MAEH1215ADA, MAEH121575ADA Multi Alert Horn with Mechanical Tone/Strobe MASS12D, MASS12LO Electronic Sounder/Strobe MASS1215ADA, MASS121575ADA Sounder/Signaling Strobe MDL / MDLW Sync Modules for use with SpectraAlert series...
  • Page 13: System Sensor Spectralert Advance

    MODEL NUMBER & NOMENCLATURE (System Sensor) SS24LOC, SS24LOBC(beige), SS24MC Ceiling Strobe SS2415ADA, SS2475ADA, SS24110ADA, SS241575ADA Signaling Strobe SS2415ADAS, SS241575ADAS Signaling Strobe with Synch. Circuit V4R2415ADA, V4R2475ADA, V4R24110ADA, V4R241575ADA Speaker/Signaling Strobe SPH-15R, SC2415, SC241575, SC2430, SC2475, SC2495, PC2415, PC242575, PC2430, PC2475 PC2495, SP2C2415, SP2C242575, SP2C495 System Sensor SpectrAlert Advance System Sensor Spectralert Advance chimes, chime strobes, horns, horn strobes and strobes base models: CHR, CHW,...
  • Page 14: Gentex - 24Vdc

    Gentex - 24VDC Use only 24VDC devices with 24 volt control panels. MODEL NUMBER & NOMENCLATURE (Gentex) GEC-24-15, GEC-24-30, GEC-24-60, GEC-24-75, GEC-24-110, GEC-24-15/75W Horn/Strobe GES-24-15, GES-24-30, GES-24-60, GES-24-75, GES-24-110, GES-24-15/75W Strobe GMH-24 Electro-Mechanical Horn GMS-24-15, GMS-24-15-1, GMS-24-110, GMS-24-110-1, GMS-24-1575-1, GMS-24-3075, GMS24-30W, GMS24-60W Electro-Mechanical Horn with Strobe GOT-24 Multi-Tone Horn GOS-24-15-1, GOS-24-110-1, GOS-24-1575-1, GOS-24-3075-1 Multi-Tone Horn/Strobe...
  • Page 15: Cooper-Wheelock - 24Vdc

    Cooper-Wheelock - 24VDC Use only 24VDC devices with 24 volt control panels. MODEL NUMBER & NOMENCLATURE (Cooper-Wheelock) 7002T-24 Horn with Strobe AES-DL1-WM-24-VF-R, AES-EL1-WM-24-VF-R Multi-Tone Signals AES-DL1-LSM-24, AES-EL1-LSM-24 Horn Strobe AH-24, AH-24WP Horn AMT-12/24 Multi-Tone Horn AMT-24-IS-VFR, AMT-24-LS-VFR, AMT-24-LSM-VFR, AMT-241575-FR Multi-Tone Horn Strobe AS-2415, AS-2430, AS-2430C, AS-2475, AS-24110, AS-241575 Audible Strobe AS-2415W, AS-2430W, AS-2475W, AS-24110W, AS-241575W Horn/Strobe AS-24MCW-FR/FW, AS-24MCC-FR/FW Multi-Candela Appliance...
  • Page 16: Cooper-Wheelock Exceder Series

    Fire-Lite certifies the Exceder product line for synch compatibility based on documentation provided by Underwriters Laboratories. Fire-Lite requires that the current draw data from legacy products (RSS, AS, NS, ZRS, and ZNS series) be used for the purpose of determining the number of devices allowed per circuit.
  • Page 17: Amseco

    ET90-2415C, ET90-2430C, ET90-2475C, ET90-24100C, ET70-24185W-FR Speaker with Strobe E-90-IS-24, E-90-LS-24, E-90-MS-24 Low Profile Speaker/Strobe E90-2415C, E90-2430C, E90-2475C, E90-24100C Speaker with Strobe E-7025-SL-VFR, E-7025-SLM-VFR, E-7070-SL-VFR,E-7070-SLM-VFR Speaker with Strobe E-9025-SL-CFW, E-9070-SL-CFW Speaker with Strobe ET-1070-IS-24-VFR, ET-1070-LS-24-VFR, ET-1070-LSM-24-VFR, ET-1070-MS-24-VFR Speaker with Strobe ET-1070-SL-VFR, ET-1070-SLM-VFR Speaker with Strobe ET-1080-IS-24-VFR, ET-1080-LS-24-VFR, ET-1080-LSM-24-VFR, ET-1080-MS-24-VFR Speaker with Strobe ET-1080-SL-VFR, ET-1080-SLM-VFR Speaker with Strobe ET-1090-IS-24-CFW, ET-1090-LS-24-CFW, ET-1090-MS-24-CFW Speaker with Strobe...
  • Page 18: System Sensor

    System Sensor MDLA / MDLWA Sync Modules, H24A, P1224MCA, P2415A, P241575A, P2475A, P24110A, PC2415A, PC241575A, PC2430A, PC2475A, PC24115A, PC24177AS1224MCA, S2415A, S241575A, S2475A, SC24110A, SC2415A, SC241575A, SC2430A, SC2475A, SC2495A, SC24115A, SC24177A, SSM24-6A, SSM24-8A, SSM24-10A - Alarm Bells CHWA, CHRA, HRA, HWA, SRA, SWA, SCRA, SCWA, SRHA, SWHA, SCRHA, SCWHA, P2RA, P2WA, PC2RA, PC2WA, P4RA, P4WA, PC4RA, PC4WA, CHSRA, CHSWA Gentex Strobe lights, synchronizable type, Models ST24-15, -15/75, -30, -60, -75, -110;...
  • Page 19: Automatic Water Control Valves (Fm-Approved) For Preaction And Deluge Sprinkler Releasing Applications

    Automatic Water Control Valves (FM-Approved) For Preaction and Deluge Sprinkler Releasing Applications (Section not recognized by UL) S2000 (TC-2F/TC-4F) S200 (TC-2F/TC-4F) Canada Only MRP-2001(E) Refer to the FM approval guide for automatic water control valves which are compatible with solenoids listed. Manufacturer Model Voltage...
  • Page 20: Door Holders

    Honeywell / Skinner 701X7028 Kidde-Fenwal 890181 2000 Kidde-Fenwal 486500 Kidde-Fenwal 895630 2000 Kidde-Fenwal 897494 1500 Minimax 88 7363 1040 Minimax 88 5738 1040 † Minimax 88 9323 Snap-Tite 2823A-2NB-A4F6 Snap-Tite 2823A-2NB-A4F5 PA0036-A Versa CGS-4232-NB3-S2 Victaulic 753E Victaulic Viking 11591 Viking 11595 Viking 11592NC...
  • Page 21: Relays

    Relays MANUFACTURER MODEL Current (mA) Air Products & Controls, LTD MR-101/C MR-201/C PAM-1 PAM-2 PAM-SD System Sensor A77-716B PR-1 PR-2 PR-3 EOLR-1 R-10T R-14T R-20T R-24T R-10E R-14E R-20E R-24E SLC Loop Surge Surpressors (UL Compatible) Surge supppressors are not required in Canadian applications. MANUFACTURER Model Number Ditek...